NEXON AMT BS VI DTC Troubleshooting Guide Version: 2.3 Date: 23-07-2019 Author: Rahul N Page: 440 of 442 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. 126 P1844 - 07 Grid Self tuning Procedure – Error -Wiring harness problem -Wrong execution conditions -Wiring Harness Connections - TCU 127 P080A - 07 Kiss point Self tuning Procedure – Error -Wiring harness problem -Wrong execution conditions -Wiring Harness Connections - TCU 128 P185B - 07 Clutch Stroke Self tuning – Error -Wiring harness problem -Clutch assembly 129 P1886-07 -Dual Port RAM Check -Hardware damage - TCU damage 130 U0001-01 -CAN EMS Error - Wiring harness problem -Electromagnetic interference -High frequency noise. 131 C0082-00 ABS Status CAN signal Invalid -ABS Unit Problem -Check ABS Service Manual 132 U0001-88 Vehicle Communication Bus - Bus off - Wiring harness problem CAN_H and CAN_L wires 133 U0121-08 Lost communication with Antilock Braking System- ABS Bus signal/ Message Failure -At least a message of ABS node is missing. -Disconnection of the ABS connector -CAN_H and CAN_L lines open at TCM connector end 134 U0155-08 Lost communication with Instrument Panel Cluster Module- Bus signal/ Message Failure -At least a message of IPC node is missing. -Disconnection of the IPC connector -CAN_H and CAN_L lines open at TCM connector end 135 U0100-08 Loss of communication with Engine Control Module- Bus Signal/ Message Failure -At least a message of EMS node is missing. -Disconnection of the IPC connector -CAN_H and CAN_L lines open at TCM connector end 136 P1C10-01 Invalid Data Received From ECM-Cyclic Redundancy Check Error -EMS (106 frame)Checksum different from that one received -Electromagnetic interference - High frequency noise 137 P1C11-02 Invalid Data Received From ECM -Message Rolling Counter Error -EMS (106 frame) rolling counter does not change in two consecutive frames. -Electromagnetic interference - High frequency noise. 138 P1C12-01 Invalid Data Received From ECM-Cyclic Redundancy Check Error -EMS(108 frame)Checksum different from that one received -Electromagnetic interference - High frequency noise. 139 P1C13-02 Invalid Data Received From ECM-Message Rolling Counter Error -EMS (108 frame) rolling counter does not change in two consecutive frames. -Electromagnetic interference - High frequency noise. 140 P1C14-01 Invalid Data Received From IPCCyclic Redundancy Check Error -IPC(197 frame)Checksum different from that one received -Electromagnetic interference
RkJQdWJsaXNoZXIy MTIwNTUz