NEW NEXON EV MY24 SERVICE MANUAL

2. I-VBAC SPECIFICATIONS SYSTEM DESCRIPTION SPECIFICATIONS General System iVBAC 2.0 Type 4 Channel ABS system with 4 wheel speed sensor Stroke 36mm (18/18) Control Microprocessor based ECU Hydraulic Control Unit (HCU) Type Diagonal (X) split Hydraulic control method Decoupled Brake System, Hydraulic Backup mode 3 modes for hydraulic control - Pressure Increase/ Hold/ Decrease Type of pump Two piston pump Type of motor DC Electronic Control Unit (ECU) Operating voltage 12 V Operating temperature - 40 °C to + 120 °C ABS sensors Type Anisotropic magneto-resistance (AMR) Principle Resistance High resistance > 3.5MΏ Air Gap Front Axle = 0.3 mm to 1.7 mm Air Gap Rear Axle = 0.45 mm to 1.35 mm Operating temperature - 40 °C to + 115 °C BRAKES 2

RkJQdWJsaXNoZXIy MTIwNTUz