IC Replacement and Flashing Specification for Nexon EV programs TITLE: IC Replacement and Flashing Specification for Nexon EV programs Document number: TBD Date: 26/12/2019 Version: V1.0 Page: 18 of 21 Prepared: Shival Checked: Shivani/Zaheer Approved: Anand Sikchi This specification is the exclusive property of Tata Motors Limited. Without their consent it may not be reproduced or given to third parties. The above specifications are subject to change and therefore suppliers are requested to refer the latest one. CONTROLLED COPY FOR RESTRICTED CIRCULATION © TATA MOTORS LTD. 5. Nexon EV IC Flashing Strategy when IC is functioning (Online) Following are the steps to Re-flash the IPC ECU. Step 1: Make the IGN ON. Note down the value of Odometer in IPC. Step 2: Re-Flash From USB A) Pre-Condition 1. Ensure USB has a valid software flash file in root folder & flash file should be in supported format and with the supported USB with device memory within 16 GB. 2. Ensure that IGN status is in ON condition and vehicle battery is in good condition 10V-16V. B) Procedure 1. Insert USB in to USB location provided on the rear side of Instrument Cluster. 2. IC will Auto detect the USB & display USB device detected as line 1 and sw Package Validation is in progress in line 2. 3. Once sw validation gets competed IPC will display sw Package Validation successful as line1 and Turn IGN Off to proceed flashing as line 2. 4. Turn Off the IGN. 5. IPC will display SOFTWARE UPDATE screen with current sw version XXX.XX.XX and if want to flash new SW , we need to select “YES” option using Steering Wheel Switches.