NEXON EV MAX SERVICE MANUAL - DTC

Gravitas/SAFARI/X451/NEXON FATC DTC Troubleshooting Data Version: 1.1 Date: 28-Apr-2021 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Author: ERC Page: 182 of 244 Component Details: N/A Preliminary Checks: 1. Voltage at the battery terminals should be greater than 9V at the Ignition ON Condition. 2. FATC power supply connector should have greater than 9V for normal functionality of FATC. 3. Check battery cable and FATC connector terminals for damage. 4. Check CCMfor pin bend/damage. Trouble Shooting:-