NEXON EV MAX SERVICE MANUAL - DTC

NEXON 2.0 EV DTC Troubleshooting Document for VCU Version: 1.0 draft Date: 31-Jan-2022 Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. P3016 - 85: - DC Charging Inlet temperature sensor 1 - signal above allowable range Overview: ISO Code P3016-85 Customer Symptom DC Fast charging is stopped. Slow charging may not occur if there is issue (short to battery) in harness connecting charging socket to VECU Fault Effects (On Vehicle) The vehicle is drivable. DC fast charging will not occur and slow charging may not take place in vehicle if this detect is active Lamp Status (If Any) Vehicle charging symbol ( ) is not seen when charging gun is plugged in vehicle charging inlet socket. Fault Detection Condition When Charging inlet temperature sensor 1 is short circuit to battery line Normal Operating Condition DC fast charging is ON when fast charging gun is plugged in. Probable Trouble Area LV wiring Harness Vehicle inlet DC charging line temperature sensor 1 mounting Powertrain VCU connector Healing Condition If DTC trigger condition is healed, DTC is present only in memory. Component Details: DC Charging Inlet temperature sensor 1 to detect the temperature of the DC positive inlet line of charging interface. Preliminary Checks: Check wiring connections to the sensor Check the connectors connecting to VCU Physically inspect sensor for damage Trouble Shooting: - Ensure vehicle is in ignition OFF mode. LV battery is disconnected. Step No. Description Check point If Yes If No