NEXON 2.0 EV DTC Troubleshooting Document for VCU Version: 1.0 draft Date: 31-Jan-2022 Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. Trouble Shooting: - 1. Remove the LV battery connections. Step No. Description Check point If Yes If No 1. Remove the LV connector of PDU Check continuity between PDU connector’s input pin 1 and 2 Go to Step 2 Problem is in the PDU. Action: Replace the PDU and Go to step 1. 2. Remove VCU side and PDU side LV connectors Check if there is continuity between these connectors No problem in the wiring between the PDU connector and VCU connector. Go to Step 3 Issue is between the PDU to VCU wiring harness Action: replace wiring harness 3. If there are any inline connectors, remove each of them Check if there is continuity between consecutive connectors No problem in wiring between the inline connectors Go to Step 4 Issue is between the PDU to VCU wiring harness inline wiring harness Action: replace wiring harness 4. Remove the VCU connector. Check if there is a continuity between A25 Pin No. of VCU and the ground (Chassis). Problem in VCU connector. Change VCU connector Action: Go to step 4