NEXON 2.0 EV DTC Troubleshooting Document for VCU Version: 1.0 draft Date: 31-Jan-2022 Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. Electric coolant pump and its pin details Pump can recognize stall or over-current if the internally measured current of the pump exceeds ILimit. There are 3 detection scenarios observed with over current which are discussed in detail below. Detection Scenario Reaction Diagnosis Stall After a recognized stall, the pump is switched off. After a certain time, a restart attempt is performed. Restart attempts will take place after certain pause times, if a stalled pump is permanently detected. In case of a stalled pump, a diagnosis will be sent Check Troubleshooting table for healing Over-current derating The over-current derating can be activated only in the speed-controlled operation of the pump. The over-current derating is activated if the internally measured current of the pump exceeds ILimit. With activated over-current derating the current consumption is limited to ILimit. No diagnosis will be sent to VCU but pump will rotate with reduced speed over-current shutdown After an overcurrent is detected with an actuated pump, the pump is switched off immediately. When the pump is off and the overcurrent is no longer present, a restart attempt takes place after a certain time. If the overcurrent is detected repeatedly, the pump is switched off again and performs restart attempts after certain time intervals. In case of an over-current shutdown, a diagnosis will be sent Check Troubleshooting table for healing