NEXON 3.0 EV DTC Troubleshooting Document for VCU Version: 2.0 Date: 22-Sep-2023 Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. Trouble Shooting: - Step No. Description Check point If yes If No 1. Remove the VCU and vehicle inlet connectors. Connect all the inline connectors between VCU and vehicle inlet and check for end-toend continuity in harness Check if there is a continuity between 1. VCU connector C776A Pin 49 and the vehicle inlet temperature sense line (Connector C448A- pin 11) 2. VCU connector C776A Pin 13 and the vehicle inlet temperature sense line - ground (Connector C448A- pin 12) Connection is okay Go to step 2 Check for harness damage and replace the harness 2. Check the short to ground at sensor Check the ambient temperature and measure the voltage between sensor pins using multimeter. Map the voltage of the sensor with the table given below If thermistor resistance is not the threshold value, Problem is with sensor Action: Replace the sensor Go to step 3 3. Check for the short at VECU pin side Check the connectivity between K49 pin to GND NOTE: Default value of AC Inlet Neutral line Temp Sensor Count Value at room temperature should be between 135 to 150 (For 25 deg C to 30 deg C) Short circuit to GND at VECU pin Problem with VECU pin Action: Replace VECU End
RkJQdWJsaXNoZXIy MTIwNTUz