NEW NEXON EV DTC MANUAL

`276 Author: Navya Krishnan/Satyajit Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. Kanger 2.0 DTC Troubleshooting Data Version: 1.0 Date: 15-Feb-2022 P19D205:- OBC Low Temp Shutdown Overview: ISO Code (If applicable) P19D205 Customer Symptom NA Fault Effect (On Vehicle) OBC will stop charging HV battery Lamp Status (If Any) NA DTC Detection Condition DTC logged if OBC Detect temperature measurement below -40 degrees Celsius Normal Operating Condition OBC Detect temperature rise above -35 degrees Celsius Probable Trouble Area 1. Temperature sensor failure in OBC. 2. Low coolant level. Healing Condition Disconnect the gun and connect back after VCU sleep Write up for the system:- The component 3in1( DC-DC Converter, On-Board Charger and Power distribution unit)is used to charge LV battery, HV battery and act as junction box between HV power train components ( PTC, e-Compressor, HV battery, Fast Charging and MCU)