NEW NEXON EV DTC MANUAL

`126 Author: Navya Krishnan Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. Kanger 3.0 DTC Troubleshooting Data Version: 1.0 Date: 24-July-2023 P19D209:-DCDC CRC Failure Overview: ISO Code (If applicable) P19D209 Customer Symptom NA Fault Effect (On Vehicle) DCDC Converter is not charging LV battery. Vehicle stops when LV battery is completely drained Lamp Status (If Any) NA DTC Detection Condition This DTC gets logged if Check the message of 0x305 and 0x360; 1. Receive 10 consecutive can message verification error 2. Received counter difference ≥ 4 Normal Operating Condition Checksum verification: the checksum verification is correct for 10 consecutive times before recovery; Counter verification: it can be recovered after checking the counter for 10 times; Probable Trouble Area 1.vehicle communication is disturbed 2.VCU Sent Wrong CRC and Alive Counter Healing Condition Ignition OFF wait till VCU sleeps & Ignition ON Write up for the related system:- The component 3in1( DC-DC Converter, On-Board Charger and Power distribution unit)is used to charge LV battery, HV battery and act as junction box between HV power train components ( PTC, e-Compressor, HV battery, Fast Charging and MCU)

RkJQdWJsaXNoZXIy MTIwNTUz