NEW NEXON EV DTC MANUAL

Nexon_WPCF ECU Service guide and replacement procedure  Locate WPCF module from top side in given cut out and locator at 2 position in X dir. of trim.  Tightening torque 2.5 ±0.2 Nm for flange head self-tapping Screw.  Assemble Tray on trim cover and with the help of locator & A-Clip feature.  Maintain the trim and ECU surface flushness of 0.5mm.  Follow the mounting location guidelines as below: Figure 20: Mounting Location Guidelines 9) Connect back the wiring harness connector to the WPCF ECU connector. 10) Ensure that harness connector for the WPCF ECU connector is fitted tightly with applicable torque mentioned on the component drawing. 11) Assemble back the trim panel in console area. 12)Assemble design intended anti-skid mat in trim from top side with the help of snap feature. Title: Nexon_WPCF ECU Service guide and replacement procedure Spec Num 2921 XX XXX A XXXXTBD Date: 28-Jan-2022 Version: 2.2 Page: 23 of 25 Prepared: Swati Yogi/Ganesh G. Checked: Awanish T. Approved: Himanshu Saxena This specification is the exclusive property of Tata Motors Limited. Without their consent, it may not be reproduced or given to third parties. The above specifications are subject to change and therefore suppliers are requested to refer the latest one. CONTROLLED COPY FOR RESTRICTED CIRCULATION © TATA MOTORS LTD.