TATA BSVI Gasoline_Bifuel Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 1.9 Date: 24-01-2022 Prepared By: Veer K. Singh / Prudhvi B Varma Checked By: Yeshwant Jadhav Approved By: Sanjeev M. Document Part No: 2921 02 xxx xxxx Page: 1159 of 1692 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. P1E03-01: Engine Start Stop system fault-General electric failure Overview: ISO Code P1E03-01 Customer Symptom 1.ESS Autostop/Autostart function not work. 2.Auto Stop Inhibition because of Stop Start related Sensors fault. Fault Effects (On Vehicle) 1.ESS Autostop/Autostart function not work. 2.Auto Stop Inhibition because of Stop Start related Sensors fault. Lamp Status (If Any) NIL Fault Detection Condition Auto Start Stop Switch is disabled Auto Start Stop LED lamp indication disabled Normal Operating Condition Auto Start Stop function enabled Auto Start Stop LED lamp indication light functional Probable Trouble Area Engine Start stop system Healing Condition After 1 driving cycle and Ignition ON. Fault is healed Fault Permanent Deletion 1. Scan tool Service 14 2. Stack Over Flow. 3. 40 warm up cycles. 4. ECU flashing 5. ECU power fail Component Details: It is a non latch able switch. Its operating temperature is -40 to 85 deg C and operating voltage is 9 to 16V. Its lifecycle is 1,00,000 cycles. Preliminary Checks: 1) Check the ESS Autostop/ Autostart related Sensors Error. 2) Check the respective sensor Connections as below. 3) Check Engine is in limp mode.