TATA BSVI Gasoline_Bifuel Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 1.9 Date: 24-01-2022 Prepared By: Veer K. Singh / Prudhvi B Varma Checked By: Yeshwant Jadhav Approved By: Sanjeev M. Document Part No: 2921 02 xxx xxxx Page: 1419 of 1692 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Transfer Function of Pressure Sensor: Uout= (c1*pabs+c0).US Where, Uout = signal output voltage in V US = supply voltage in V pabs = absolute pressure in kPa c0 = -0.1/105 c1 = 0.85/105 kPa Characteristics of Pressure Sensor: Characteristics of Pressure Sensor with Supply Voltage of 5 Volts