Vehicle Platform & ECU Name DTC Troubleshooting Data Ver: 1 Date: 23/11/2022 Author: ERC Page 193 of 834 Copyright by TATA MOTORS Ltd. This document must not be used in any w ay, such as copying and redistributing to third parties, w ithout our consent electrical faults related to EGR should be present Step 7 If the problem persists, replace the EGR Module - Associated Parameters: Parameter Label Description DID Monitoring Position Demand for EGR valve Position Demand for HP EGR valve FEB F “Position Demand for EGR valve” and “EGR position feedback” should match with <1% error EGR position feedback HP EGR valve Feedback position FEC1 First close position counts learnt EGRH 1st close position counts learnt for EGRH FEC3 Normal range – 150 to 250 cnts First open position counts learnt EGRH 1st open position counts learnt for EGRH FEC4 Normal range – 850 to 950 cnts Current close position counts learnt EGRH Current close position counts learnt for EGRH FEC5 Normal range – 150 to 250 cnts Current open position counts learnt EGRH Current open position counts learnt for EGRH FEC6 Normal range – 850 to 950 cnts Verification condition: Warm up the engine above 80degC and do key off till power latch twice and check whether the fault is cleared. Circuit Description: ECM in accordance with engine and driving conditions gives a electric output to directly drive a DC motor (Part of EGR module) which in turn drives the EGR valve. Hence ECM indirectly controls the opening and closing of EGR valve. EGR plays an important role in emissions control by altering rate of flow of exhaust gases from exhaust manifold. Circuit Schematic Diagram: