Vehicle Platform & ECU Name DTC Troubleshooting Data Ver: 1 Date: 23/11/2022 Author: ERC Page 270 of 834 Copyright by TATA MOTORS Ltd. This document must not be used in any w ay, such as copying and redistributing to third parties, w ithout our consent Step 5 Perform SPCS using service tool and check the learnt MDP offset values. Check again, Whether the fault repeats Coolant temperature > 70 deg C Step 6 Then drive the vehicle in 3rd gear to vehicle speed above 60kmph, then release the accelerator pedal till the vehicle speed drops to 30kmph. Avoid applying brake unless required. Repeat this driving cycle number of times at least 15 to 20 minutes. Coolant temperature > 70 deg C Step 7 Switch off the ignition switch, wait for 60 seconds, start the engine and drive the vehicle. Fault code should not re-appear. - Step 8 If the fault repeats, replace the injector. - Verification condition: Drive the vehicle in city and highway condition as mentioned in step 5. Component Details: The Solenoid Valve Injectors are used to inject the desired fuel quantity based on the engine operating conditions into the combustion chamber. They are mounted at the cylinder head above the combustion chamber. Circuit Schematic Diagram: NA Component Location and Image: Sample C3I image: