Vehicle Platform & ECU Name DTC Troubleshooting Data Ver: 1 Date: 23/11/2022 Author: ERC Page 414 of 834 Copyright by TATA MOTORS Ltd. This document must not be used in any w ay, such as copying and redistributing to third parties, w ithout our consent P006E- 00: Turbocharger/Supercharger Boost Control "A" Supply Voltage Circuit Low Overview: Code Cause Effect on Vehicle Fault Code: P006E-00 1. ECU connection 2. ECU hardware malfunction 1. CE lamp ON 2. Reduced vehicle performance 3. Higher engine noise may observed Lamp status: Check Engine Lamp on Malfunction Indicator Lamp off Checkpoints: Check Battery Voltage at Ignition off (Nominal Range 11.5V~12.8V) Trouble Shooting Steps: Sr. No. Steps Specifications Step 1 Check ECU connector connected properly Physical check Step 2 Check all sensor connectors are connected properly & working correctly Physical check Step 3 If the problem persists, replace the ECU Circuit Description: ECM continuously monitors its internal memory status, internal circuits. These are basically self-checks that insure that ECM is functioning properly. If any malfunction is detected, ECM will set the DTC. ECM is supplied voltage from the battery positive supply through Main relay. ECM ground connection is connected to the battery negative supply. ECM functionality critically depends on ensuring proper ground connection.