Nexon MCE 2 Gen3 Digital Instrument Cluster DTC Troubleshooting Data Version: 1.0 Date: 12-June-23 Author: Vasant Date Page: 22 of 135 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Connector View & Information: - Battery Ground (Pin no.J1-04) FLS Sig Gnd (Pin no.J1-13) FuelLvlSensSig(Pin.No.J1-11) Inspection Method: - Check the FLS sensor input to the cluster in Ohms through Multi meter.