NEW NEXON DTC MANUAL

Nexon_WPCF ECU Service guide and replacement procedure Title: Nexon_WPCF ECU Service guide and replacement procedure Spec Num 2921 XX XXX A XXXXTBD Date: 22-May-2021 Version: 2.1 Page: 14 of 24 Prepared: Swati Yogi Checked: Awanish T. Approved: Himanshu Saxena This specification is the exclusive property of Tata Motors Limited. Without their consent, it may not be reproduced or given to third parties. The above specifications are subject to change and therefore suppliers are requested to refer the latest one. CONTROLLED COPY FOR RESTRICTED CIRCULATION © TATA MOTORS LTD. o Check if Smart phone device protection cover is used which are non-standard, metallic, or very thick, as it reduces the charging efficiency. Smart phone back cover thickness should not exceed 1mm as it will not halt charging. o Metallic cover may halt the charging function. o Check if Wireless charger is correctly fitted with trim maintaining the gap of <3 from charger surface to anti-skid mat surface and flushness of 0.5mm i.e gap between trim and ECU surface. o No waviness shall be observed on Anti-skid mat surface. Figure 8: Critical dimensions while fitment o With all the above checks check for the “charging on” message on the HU. Charging shall start with Pop up on HU screen. After pop up an all-time indication of charging status on HU status bar shall appear.