TATA BSVI Gasoline_Bifuel Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 2.6 Date: 5-10-2023 Prepared By: Pradip Shimpi Checked By: Yeshwant Jadhav Approved By: Sanjeev M. Document Part No: 2921 02 xxx xxxx Page: 1719 of 1720 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. 319 P0192-11 Natural Gas Rail pressure sensor Circuit Low - Circuit Short to Ground 1556 NO 320 P1300-92 Misfire detected in Gasoline mode 1559 NO 321 P0301-92 Misfire detected on cylinder 1 in gasoline mode 1564 NO 322 P0302-92 Misfire detected on cylinder 2 in gasoline mode 1569 NO 323 P0303-92 Misfire detected on cylinder 3 in gasoline mode 1574 NO 324 P1301-92 Misfire detected in Gas operating mode 1579 NO 325 P0301-92 Misfire detected in Gas operating mode, cylinder 1 1584 NO 326 P0302-92 Misfire detected in Gas operating mode, cylinder 2 1589 NO 327 P0303-92 Misfire detected in Gas operating mode, cylinder 3 1594 NO 328 P0093-7A CNG large leak from Low pressure system 1599 NO 329 P0094-7A CNG fine leak from Low pressure system 1604 NO 330 P0183-15 CNG rail temperature sensor circuit High - Circuit Short to Battery or open circuit 1609 NO 331 P0182-11 CNG rail temperature sensor circuit Low - Circuit Short to Ground 1613 NO 332 P0181-29 Signal Plausibility Failure - Voltage Non plausible 1617 NO 333 P061D-29 Fuel mixture plausibilisation error in CNG operation - Signal invalid 1622 NO 334 P061D-62 Fuel mixture correction factor error in CNG operation 1627 NO 335 U04A0- 83 Invalid Data Received From Transmission control unit - value of signal protection calculation incorrect 1632 NO 336 U04A0- 82 Invalid Data Received From Transmission control unit - Alive / Sequence Counter Incorrect / Not Updated 1634 NO 337 U04A1- 83 Invalid Data Received From Transmission control unit - value of signal protection calculation incorrect 1636 NO 338 U04A1- 82 Invalid Data Received From Transmission control unit - Alive / Sequence Counter Incorrect / Not Updated 1638 NO 339 U04A2- 83 Invalid Data Received From Transmission control unit - value of signal protection calculation incorrect 1640 NO 340 U04A2- 82 Invalid Data Received From Transmission control unit - Alive / Sequence Counter Incorrect / Not Updated 1642 NO 341 P1C01-81 Invalid Serial Data received from Transmission control unitDCT Clutch, Gear and Target gear Plausibility Check 1644 NO 342 P1C02-81 Invalid Serial Data received from Transmission control unitEngiune rpm intervention Plausibility Check 1646 NO 343 P1C03-81 Invalid Serial Data received from Transmission control unitGear Box Mode Plausibility Check 1648 NO 344 P1C04-81 Invalid Serial Data received from Transmission control unitGear Shift lever Plausibility Check 1650 NO 345 P1C05-81 Invalid Serial Data received from Transmission control unitTorque Request and Torque Intervention Plausibility Check 1651 NO
RkJQdWJsaXNoZXIy MTIwNTUz