NEXON CNG - DTC CODES

X104 CNG (Nexon) 4” Instrument Cluster DTC Troubleshooting Data Version: 2.0 Date: 19-August-24 Author: Suraj Shivsharan Page: 10 of 160 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Trouble Shooting:- DTC’s confirmation:- After rectification, ensure the following points before handing over the system to the customer a) Battery voltage should be 9-16v. b) Ensure ECU connector is place correctly. Turn ON Ignition. Connect the TML Diagnostic Tool. Check the status of DTC’s (Memorized/Current) Record the DTC & Clear DTC’s Turn Ignition OFF & ON Verify If DTC B190B -11 is present Is DTC B190B-11 is Present? Check for continuity between Pin No.J1-10(GND) & J1-29 of ECU Connector. Is Continuity Present? OAT input is Short Circuit to Ground. Rectify Fault at wiring Harness & wait for 20sec to recover the fault. Clear the DTC. Verify the function of OAT Sensor with multimeter & OAT value on LCD display. Clear the DTC from the ECU memory. Turn Ignition OFF & ON. Press the mode switch button one time to show the OAT display value & Check whether display is showing the OAT value in Deg’ C. Stop Stop YES NO YES NO Stop