NEXON CNG - DTC CODES

TATA BSVI Gasoline_Bifuel Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 2.6 Date: 5-10-2023 Prepared By: Pradip Shimpi Checked By: Yeshwant Jadhav Approved By: Sanjeev M. Document Part No: 2921 02 xxx xxxx Page: 13 of 1720 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. P0342-11: Camshaft Position Sensor "A" Circuit Low Bank 1- Circuit Short to Ground ............................ 1298 P0321-07: Ignition/Distributor Engine Speed Input Circuit Range/Performance ......................................... 1306 P2231-1F: O2 Sensor Signal Circuit Shorted to Heater Circuit Bank 1 Sensor 1 ....................................... 1308 P0606-12: Control Module Processor – Circuit Short to Battery .................................................................... 1315 P0133-7C: O2 Sensor Circuit Slow Response bank 1 Sensor 1 .................................................................... 1317 P2626-13: O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1- Circuit Open ..................... 1323 P2237-13: O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 .......................................... 1329 P2251-13: O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 -Circuit Open ................ 1335 P0130-01: O2 Sensor Circuit Bank 1 Sensor 1-General Electrical Failure................................................... 1342 P2227-22: Barometric Pressure Circuit Range/Performance – Signal Amplitude>Maximum ................... 1348 P2196-26: O2 Sensor Signal Biased/Stuck Rich .............................................................................................. 1351 P2195-27: O2 Sensor Signal Biased/Stuck Lean ............................................................................................. 1357 P2414-76: O2 Sensor Exhaust Sample Error Bank 1 Sensor 1- Wrong Mounting Position ...................... 1363 P3300-01: IBS internal error- General Electrical Failure ................................................................................. 1368 P0563-17: System Voltage High-Circuit voltage above threshold ................................................................. 1372 P0562-16: System Voltage Low-Circuit voltage below threshold ................................................................... 1376 P0606-11: Control Module Processor – Circuit Short to Ground ................................................................... 1380 P0606-49: Control Module Processor – Internal Electronic Failure ............................................................... 1382 P0606-13: Control Module Processor – Circuit Open ...................................................................................... 1384 P0328-15: Knock/Combustion Vibration Sensor 1 Circuit High Bank 1 or Single Sensor- Circuit short to battery or open ....................................................................................................................................................... 1386 P0327-14: Knock/Combustion Vibration Sensor 1 Circuit Low Bank 1 or Single Sensor-Circuit short to ground or open ....................................................................................................................................................... 1393 U1305-88: LIN Bus Communication-Bus off ...................................................................................................... 1400 P2237-64: O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 – Signal Plausibility Failure ...................................................................................................................................................................... 1401 P2237-13: O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 .......................................... 1407 P2227-21: Barometric Pressure Circuit Range/Performance - Signal Amplitude<Minimum ..................... 1413 P0106-22: Manifold Absolute Pressure Circuit Range/Performance - Signal Amplitude>Maximum ........ 1416 P2176-00: Throttle Actuator Control System – Idle Position Not Learned-no sub type information ......... 1424 P0135-01: O2 Sensor Heater Circuit Bank 1 Sensor 1-General Electrical Failure ..................................... 1432 P2243-13: O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 - Circuit Open .......................... 1437 P1E0A-13: PWM Blower Output failure - Open Circuit .................................................................................... 1444

RkJQdWJsaXNoZXIy MTIwNTUz