IPC Specific Diagnostic Specification for Nexon MCE 2 CNG 4” Digital Cluster program 11 4724 Wireless Charger Enable/Disable 12 4757 Rear SBR Configuration 13 4727 Driver SBR Configuration 14 4752 CNG Signal Configuration Step 5: Odometer Learning: IC shall learn odometer value automatically from Immobiliser, in case if the immobiliser is not replaced, the Odometer need not be written in IC. If immobiliser is also replaced, Odometer must be written manually using DID 4666. Step 6: Service Reminder Requirements: Service Information Reset (3f00) routine must be run. Interval and Pop up must be written in DID 4628 as per below table with respect vehicle platform: Vehicle Platform Service Interval Distance Service Interval Time Service Pop Distance Service Pop Time Nexon MCE 2 7500 180 500 30 Step 7: Poke-yoke for 16R PLM part numbers: a) Download VC data from PLM, which should contain 16R part numbers. b) Read following DIDs from New cluster and compare them with Downloaded VC Data. Sr No DID Parameter Name 1 7234 ECU Assembly number 2 F187 Vehicle manufacturer Spare part number 3 7243 Configuration Part Number 4 723F ECU SBL Part Number 5 7241 ECU Application Software Number TITLE: IPC Specific Diagnostic Specification for Nexon MCE 2 CNG 4” Digital Cluster program Document number: TBD Date: 22-08-2024 Version: V1.0 Page: 14 of 17 Prepared: Suraj Shivsharan Checked: Jagadish Ghodake Approved: Sanjay Jaisingh This specification is the exclusive property of Tata Motors Limited. Without their consent it may not be reproduced or given to third parties. The above specifications are subject to change and therefore suppliers are requested to refer the latest one. CONTROLLED COPY FOR RESTRICTED CIRCULATION © TATA MOTORS LTD.