yϭϬϰ KƐƉƌĞLJ /ŶƐƚƌƵŵĞŶƚ ůƵƐƚĞƌ

d dƌŽƵďůĞƐŚŽŽƚŝŶŐ ĂƚĂ

sĞƌƐŝŽŶ͗ ϭ͘ϯ

ĂƚĞ͗ ϮϬͲDĂƌĐŚͲϭϳ

Author: Balaji / Amar /

Nitin / Umapathi /

Deepak

Page: 131 of 138

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

U0424-81:- Invalid Data Received From HVAC

Overview:-

ISO Code

U0424-81

Customer Symptom

No customer symptom

Fault Effects (On Vehicle)

No effects.

Lamp Status (If Any)

N.A

Fault Detection Condition

Relevant functional DTCs present in HVAC

Normal Operating Condition

HVAC ECU sends correct data in normal condition.

Probable Trouble Area

Incorrect data received from HVAC.

Healing Condition

After rectifying all the functional failures in the HVAC

ECU

Trouble Shooting:-