Background Image
Table of Contents Table of Contents
Previous Page  3084 / 5157 Next Page
Information
Show Menu
Previous Page 3084 / 5157 Next Page
Page Background

PSCM

DTC Troubleshooting Guide for Nexon

Version: 1.1

Date: 21/06/2017

Author: E&E Chassis - ERC

Page: 141 of 156

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

U0423 - 82: Invalid Data Received From IPC-Message Rolling Counter Error

Overview:

ISO Code

U0423-82

Customer Symptom

No warning lamp, No heavy steering

Fault Effects (On Vehicle)

Default assistance

Lamp Status (If Any)

Warning lamp OFF

Fault Detection Condition

When vehicle speed information is not updated as per the

latest values.

Normal Operating Condition

IPC ECU sends updated data in normal condition.

Probable Trouble Area

IPC ECU

Healing Condition

When IPC sends the updated value

Component Details:

NA

Preliminary Checks:

NA