PSCM
DTC Troubleshooting Guide for Nexon
Version: 1.1
Date: 21/06/2017
Author: E&E Chassis - ERC
Page: 141 of 156
Copyright ©
TATA MOTORS Ltd.
This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.
U0423 - 82: Invalid Data Received From IPC-Message Rolling Counter Error
Overview:
ISO Code
U0423-82
Customer Symptom
No warning lamp, No heavy steering
Fault Effects (On Vehicle)
Default assistance
Lamp Status (If Any)
Warning lamp OFF
Fault Detection Condition
When vehicle speed information is not updated as per the
latest values.
Normal Operating Condition
IPC ECU sends updated data in normal condition.
Probable Trouble Area
IPC ECU
Healing Condition
When IPC sends the updated value
Component Details:
NA
Preliminary Checks:
NA