NEXON 3.0 EV DTC Troubleshooting Document for VCU Version: 2.0 Date: 22-Sep-2023 Copyright © TATA MOTORS Ltd. This document must not be used in anyway, such as copying and redistributing to third parties, without the consent of author. line Temp Sensor Count Value at room temperature should be between 135 to 150 (For 25 deg C to 30 deg C) DTC’s confirmation: - After rectification, send Clear the DTC command by using TML diagnostic tool. Ensure no DTC is in defect/ confirmed state before handing over to customer VECU Parameter Temp Value in Deg C AC Inlet Neutral line Temp Sensor Count Value 250 -40 248 -35 245 -30 242 -25 238 -20 233 -15 226 -10 219 -5 210 0 200 5 188 10 176 15 163 20 150 25 136 30 110 40 98 45 87 50 76 55 67 60 58 65 51 70 44 75 39 80 34 85 29 90 25 95 22 100 19 105 17 110