NEXON CNG - DTC CODES

TATA BSVI Gasoline_Bifuel Program – EMS ECU Bosch DTC Troubleshooting Service Manual Version: 2.6 Date: 5-10-2023 Prepared By: Pradip Shimpi Checked By: Yeshwant Jadhav Approved By: Sanjeev M. Document Part No: 2921 02 xxx xxxx Page: 1717 of 1720 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. 262 P0343-12 Camshaft Position Sensor "A" Circuit High Bank 1- Circuit Short To Battery 1290 NO 263 P0342-11 Camshaft Position Sensor "A" Circuit Low Bank 1- Circuit Short to Ground 1298 NO 264 P0321-07 Ignition/Distributor Engine Speed Input Circuit Range/Performance 1306 NO 265 P2231-1F O2 Sensor Signal Circuit Shorted to Heater Circuit Bank 1 Sensor 1 1308 NO 266 P0606-12 Control Module Processor – Circuit Short to Battery 1315 NO 267 P0133-7C O2 Sensor Circuit Slow Response bank 1 Sensor 1 1317 NO 268 P2626-13 O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1- Circuit Open 1323 NO 269 P2237-13 O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 1329 NO 270 P2251-13 O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 -Circuit Open 1335 NO 271 P0130-01 O2 Sensor Circuit Bank 1 Sensor 1-General Electrical Failure 1342 NO 272 P2227-22 Barometric Pressure Circuit Range/Performance – Signal Amplitude>Maximum 1348 NO 273 P2196-26 O2 Sensor Signal Biased/Stuck Rich 1351 NO 274 P2195-27 O2 Sensor Signal Biased/Stuck Lean 1357 NO 275 P2414-76 O2 Sensor Exhaust Sample Error Bank 1 Sensor 1- Wrong Mounting Position 1363 NO 276 P3300-01 IBS internal error- General Electrical Failure 1368 NO 277 P0563-17 System Voltage High-Circuit voltage above threshold 1372 NO 278 P0562-16 System Voltage Low-Circuit voltage below threshold 1376 NO 279 P0606-11 Control Module Processor – Circuit Short to Ground 1380 NO 280 P0606-49 Control Module Processor – Internal Electronic Failure 1382 NO 281 P0606-13 Control Module Processor – Circuit Open 1384 NO 282 P0328-15 Knock/Combustion Vibration Sensor 1 Circuit High Bank 1 or Single Sensor- Circuit short to battery or open 1386 NO 283 P0327-14 Knock/Combustion Vibration Sensor 1 Circuit Low Bank 1 or Single Sensor-Circuit short to ground or open 1393 NO 284 U1305-88 LIN Bus Communication-Bus off 1400 NO 285 P2237-64 O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 – Signal Plausibility Failure 1401 NO 286 P2237-13 O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 1407 NO 287 P2227-21 Barometric Pressure Circuit Range/Performance - Signal Amplitude<Minimum 1413 NO 288 P0106-22 Manifold Absolute Pressure Circuit Range/Performance - Signal Amplitude>Maximum 1416 NO

RkJQdWJsaXNoZXIy MTIwNTUz