NEXON AMT
DTC Troubleshooting Guide
Version: 2.0
Date: 24-01-2018
Author: Suraj/Anupama
Page: 431 of 434
Copyright ©
TATA MOTORS Ltd.
This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.
- alternator
104 P0604-
08
TCU ROM– Checksum Error
-TCU hardware damage
-TCU damage
105 P0604-
07
TCU RAM– Integrity Error
-TCU hardware damage
-TCU damage
106 P062F-
07
TCU EEPROM– Tuning Data
Alteration Error
-TCU hardware damage
-TCU damage
107 P062F-
08
TCU EEPROM– Grid Data
Alteration Error
-TCU hardware damage
-TCU damage
108 P1740-
07
TCU EEPROM– System Data
Alteration Error
-TCU hardware damage
-TCU damage
109 P060A-
07
Safety Microprocessor–
Integrity failure
-Hardware damage
-SMP(safety microprocessor) output
problem
-TCU damage
110 P060A-
08
Safety Microprocessor– Output
failure
-Hardware damage
-SMP(safety microprocessor) output
problem
-TCU damage
111 P0701-
02
Electro valves Driver 1– SPI
Device fault
-TCU hardware damage
-TCU damage
112 P0701-
01
Electro valves Driver 1–
Thermal warning
-TCU hardware damage
-TCU damage
113 P0701-
03
Electro valves Driver 1– Device
closed
-TCU hardware damage
-TCU damage
114 P0701-
04
Electro valves Driver 1– Device
open
-TCU hardware damage
-TCU damage
115 P184D-
02
Electro valves Driver 2– SPI
Device fault
-TCU hardware damage
-TCU damage
116 P184D-
01
Electro valves Driver 2–
Thermal warning
-TCU hardware damage
-TCU damage
117 P0881-
02
TCU 12V Internal Supply –
Device Open
-TCU hardware damage
-TCU damage
118 P0881-
03
TCU 12V Internal Supply –
Device closed
-TCU hardware damage
-TCU damage
119 P0880-
04
SMP 5V power Supply – under
low threshold
-TCU hardware damage
-TCU damage
120 P0880-
06
SMP 5V power Supply – under
medium threshold
-TCU hardware damage
-TCU damage
121 P0880-
02
SMP 5V power Supply – under
low threshold
-TCU hardware damage
-TCU damage
122 P0880-
03
TCU 5V power Supply – Device
Closed
-TCU hardware damage
-TCU damage
123 P1401-
07
Level 2 Intervention-Safety
input failure
-Wiring harness problem
-Input system problem
-Wrong execution
conditions
-TCU damage
124 P1401-
08
Level 2 Intervention-system
problem
-Wiring harness problem
-System problem
-Wrong execution
conditions
-TCU damage
125 P060C-
07
Level 3 Intervention –System
problem
-Wiring harness problem
-Hardware damage
-Wrong execution
conditions
-TCU damage




