126 P1844 -

07

Grid Self tuning Procedure –

Error

-Wiring harness problem

-Wrong execution

conditions

-Wiring Harness

Connections

- TCU

127 P080A -

07

Kiss point Self tuning Procedure

– Error

-Wiring harness problem

-Wrong execution

conditions

-Wiring Harness

Connections

- TCU

128 P185B -

07

Clutch Stroke Self tuning –

Error

-Wiring harness problem

-Clutch assembly

129 P1886-

07

-Dual Port RAM Check

-Hardware damage

-

TCU damage

130 U0001-

01

-CAN EMS Error

- Wiring harness problem

-Electromagnetic

interference

-High frequency noise.

131 C0082-

00

ABS Status CAN signal Invalid

-ABS Unit Problem

-Check ABS Service

Manual

132 U0001-

88

Vehicle Communication Bus -

Bus off

- Wiring harness problem

CAN_H and CAN_L wires

133 U0121-

08

Lost communication with

Antilock Braking System- ABS

Bus signal/ Message Failure

-At least a message of ABS node is missing.

-Disconnection of the

ABS connector

-CAN_H and CAN_L lines

open at TCM connector

end

134 U0155-

08

Lost communication with

Instrument Panel Cluster

Module- Bus signal/ Message

Failure

-At least a message of IPC node is missing.

-Disconnection of the

IPC connector

-CAN_H and CAN_L lines

open at TCM connector

end

135 U0100-

08

Loss of communication with

Engine Control Module- Bus

Signal/ Message Failure

-At least a message of EMS node is missing.

-Disconnection of the

IPC connector

-CAN_H and CAN_L lines

open at TCM connector

end

136 P1C10-

01

Invalid Data Received From

ECM-Cyclic Redundancy Check

Error

-EMS (106 frame)Checksum different from

that one received

-Electromagnetic

interference

- High frequency noise

137 P1C11-

02

Invalid Data Received From

ECM -Message Rolling Counter

Error

-EMS (106 frame) rolling counter does not

change in two consecutive frames.

-Electromagnetic

interference

- High frequency noise.

138 P1C12-

01

Invalid Data Received From

ECM-Cyclic Redundancy Check

Error

-EMS(108 frame)Checksum different from

that one received

-Electromagnetic

interference

- High frequency noise.

139 P1C13-

02

Invalid Data Received From

ECM-Message Rolling Counter

Error

-EMS (108 frame) rolling counter does not

change in two consecutive frames.

-Electromagnetic

interference

- High frequency noise.

140 P1C14-

01

Invalid Data Received From IPC-

Cyclic Redundancy Check Error

-IPC(197 frame)Checksum different from

that one received

-Electromagnetic

interference