Nexon Gasoline – EMS ECU Bosch

DTC Troubleshooting Manual

Version: 0.1

Date: 26-08-2017

Prepared By: Sunu S Babu/Yogesh Jadhav

Checked By: Yeshwant Jadhav

Approved By: Satish Kumar

Document Part No: 2921 02 224 A1736

Page: 1104 of 1203

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

P3005-13: Starter Relay Feedback Circuit – Circuit Open

Overview:

ISO Code

P3005-13

Customer Symptom

Vehicle start not possible.

Fault Effects (On Vehicle)

Crank is inhibited for 10 sec, Vehicle will not Start

Lamp Status (If Any)

CE Lamp ON after 3 drive cycles

Fault Detection Condition

Ignition ON and Starter relay feedback pin of EMS ecu is Open Circuited

Normal Operating Condition

Wiring Harness connections as per Circuit schematic between EMS ecu and

Starter feedback Circuit, Starter relay Fully operational.

Probable Trouble Area

Improper Wiring Harness Connections, Starter relay Stuck Open

Healing Condition

After 1 Drive cycles

Fault permanent deletion

1. Clear DTC Command form Scan tool

2. Stack Over Flow.

3. 40 warm up cycles.

4.ECU flashing

5. ECU Power-Fail

Component Details:

Starter Relay-2 is a normally Open relay. It is an electrically controlled switch. By energizing the coil of the relay, its

contacts get closed.

Preliminary Checks:

5) Loose/ Damaged Connections between Starter relay contact pin X and EMS ecu

6) Starter Relay Faulty / Stuck Open

7) Check for back out of pins at ECU connector.

8) Check for damage of pins at ECU connector.