Nexon Gasoline – EMS ECU Bosch

DTC Troubleshooting Manual

Version: 0.1

Date: 26-08-2017

Prepared By: Sunu S Babu/Yogesh Jadhav

Checked By: Yeshwant Jadhav

Approved By: Satish Kumar

Document Part No: 2921 02 224 A1736

Page: 1129 of 1203

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

P3018-04: No response is received from ICU – System Internal Failures

Overview:

ISO Code

P3018-04

Customer Symptom

Vehicle will not start

Fault Effects (On Vehicle)

EMS ecu will disable starter motor and Fuel supply for injection

Lamp Status (If Any)

Immo Lamp ON

Fault Detection Condition

This fault gets logged when EMS doesn’t get any response CAN signal

from Immobilizer.

Normal Operating Condition

Healthy communication btw EMS and ICU

Probable Trouble Area

Wiring harness connections of Immo

Healing Condition

After 1 drive cycle of fault rectification

Fault Permanent deletion

Stack Over flow

After 40 drive cycles

Diagnostic command to clear DTC’s

Component Details:

Immobilizer system is designed to prevent vehicle theft by electronically disabling the engine starting system. The engine

can be started only with vehicle’s original immobilizer ignition key, which has an electronic identification programmed

code.

Immobilizer unit (VICM) is an add-on part on the ignition switch, fitted on the steering column. The engine can be started

only with the vehicle’s original immobilizer ignition key. The electronic key communicates the identification code to

immobilizer (VICM) when the key is turned to the "Ignition ON" position.

Immobilizer comes with two Electronic keys (E-key)

Preliminary Checks:

1. Check whether the CAN H and CAN L connections to Immobilizer are as per the schematic.

2. Check whether the Imo is getting Battery power supply.