Background Image
Table of Contents Table of Contents
Previous Page  4051 / 5157 Next Page
Information
Show Menu
Previous Page 4051 / 5157 Next Page
Page Background

TML Park Distance Controller (PDC) ECU DTC

Troubleshooting guide for Nexon

Version: 0.2

Date: 08Jun17

Author:

Ravi Teja

Page: 112 of 123

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of

author.

U3007-16:- Control Module Input Power “B” – Circuit Voltage Below Threshold

ISO Code

U3007-16

Customer Symptom

Park assist will probably not function or will

function intermittently or partially.

Fault Effects (On Vehicle)

Cannot determine scope without knowledge of

power line applicability. Note that, Park Assist

system powered on IGN line.

Lamp Status (If Any)

NA

Fault Detection Condition

If Battery voltage goes below 11.5V, If alternator

is not charging the battery and alternator voltage

is less than 13.5 or 0V

Normal Operating Condition

Normal operation voltage range is 9V - 16V.

Normal operation means, that the sensors are

working, and the obstacle distance information is

sent out via CAN messages.

Operation voltage range for CAN communication

is 7V to 18V. Degraded CAN communication is

not allowed outside this range.

Probable Trouble Area

Low Battery

Healing Condition

NA